Scene 1 / 7 09:00 WITA — Kamis, 30 April 2026 · Pak Dwi drill-down EX-04 untuk root cause analysis. KOMTRAX menunjukkan pressure hydraulic pump mulai anomali 8 hari sebelum breakdown. Kalau setup alert lebih sensitif, Foxel bisa tangkap 5-6 hari lebih awal dan schedule PM preventive — tidak CM emergency. 09:00 WITA — Thursday, 30 April 2026 · Mr. Dwi drills into EX-04 for root-cause analysis. KOMTRAX shows hydraulic pump pressure started drifting 8 days before breakdown. With tighter alert thresholds, Foxel could have caught it 5–6 days earlier and scheduled preventive PM — avoiding emergency CM.
EX-04 · Hitachi EX1200 · Analisa TelematicsTelematics Analysis
Serial 6JA-8842 · KOMTRAX ID HTR-EX04 · data dari 22/3 – 22/4 (30 hari terakhir)Serial 6JA-8842 · KOMTRAX ID HTR-EX04 · data 22/3 – 22/4 (last 30 days)
Pak Dwi Hartono
Maintenance Manager
DH
Status · Hari ke-8 CMStatus · Day 8 CM

EX-04 Hitachi EX1200 · Pit North Bench 3 · breakdown 22/4 14:00broke down 22/4 14:00

Hydraulic pump PN 4D4GH88A gagal total. Downtime 192 jam ke 30/4, revenue loss est. IDR 540 juta. Spare part tiba 30/4 16:00 dari Singapore via United Tractors. Repair Pak Kusno mulai 1/5 07:00.Hydraulic pump PN 4D4GH88A failed completely. 192 h downtime to 30/4, est. revenue loss IDR 540 M. Parts arrive 30/4 16:00 from Singapore via United Tractors. Mr. Kusno starts repair 1/5 07:00.

Umur operasiOperating age
18.240 h
unit berusia 4,2 tahun4.2 years old
MTBF 12 bln
156 h
target 240 · gap 84 jam240 target · gap 84 h
Availability YTD
77,8%
bulan ini drop ke 42%this month dropped to 42%
Cost YTD
IDR 328 jt
PM 78 + CM 250 jtPM 78 + CM 250 M
DTC bulan inithis month
14
3 kritis · 7 hi · 4 med3 critical · 7 hi · 4 med
Siklus repairRepair cycle
3 × / YTD
trend naik · perlu overhaulrising trend · overhaul due

4 Parameter Telematics — 30 Hari4 Telematics Parameters — 30 Days

breakdown titik merahred point = breakdown
Tekanan pompa hidrolik (psi)Hydraulic pump pressure (psi)
baseline 3.600 · drop 14/4 ↓ warning levelbaseline 3,600 · dropped 14/4 ↓ warning
2.840 psi
normal 3,600 warn 3,200 22/4 breakdown 14/4 ← 8 hari sebelum
Suhu oli hidrolik (°C)Hydraulic oil temp (°C)
baseline 68 · spike 18/4 ke 88 °Cbaseline 68 · spiked 18/4 to 88 °C
86 °C
normal 68 18/4 spike 88°C
Vibrasi (mm/s RMS)Vibration (mm/s RMS)
baseline 2,8 · trend naik bertahapbaseline 2.8 · steady rise
5,4 mm/s
Fuel rate (L/jam)Fuel rate (L/h)
baseline 58 L/h · naik = load kerja lebihbaseline 58 L/h · rising = harder work
68 L/h
Root Cause Analysis — Post-mortem FoxelRoot Cause Analysis — Foxel Post-mortem
8 hari peluang pencegahan terlewat8-day prevention window missed
Pressure drop linear dari 14/4 adalah signature klasik bearing pompa hidrolik memasuki fase failure. Vibrasi +30% dan temp spike 18/4 memperkuat diagnosa. KOMTRAX alert threshold saat ini (3.000 psi) terlalu rendah — baru trigger 20/4, hanya 48 jam sebelum breakdown. Rekomendasi: lower threshold ke 3.300 psi + cross-reference dengan vibrasi trend. Next excavator (EX-05) threshold sudah di-update otomatis. The linear pressure drop from 14/4 is a classic hydraulic-pump bearing failure signature. The +30% vibration and 18/4 temperature spike confirm the diagnosis. Current KOMTRAX alert threshold (3,000 psi) is too low — it only fired on 20/4, just 48 h before breakdown. Recommendation: lower threshold to 3,300 psi + cross-reference with vibration trend. The next excavator (EX-05) already has the updated threshold.

DTC Code History · 30 haridays

14
TglCodeDeskripsiSev
22/4 14:00P0016AHyd pump failure totalHyd pump total failureCRIT
21/4 08:30P0016DPressure critical lowPressure critical lowCRIT
20/4 15:22P0016PPressure low warningPressure low warningHI
19/4 11:18P0022TTemp oil highOil temp highHI
18/4 13:40P0022TTemp oil spike 88°COil temp spike 88°CCRIT
17/4 10:15V0085BVibration bearingHI
15/4 16:02V0085Vibration anomalyMED
14/4 09:48P0016Pressure driftPressure driftMED
10/4 08:30U0100CAN bus intermittentMED
9/4 ...+ 5 kode lainnya (semua low sev)+ 5 more codes (all low sev)

Timeline EventEvent Timeline

15/3/2026 · PM 500-hr
Oil change, filter replace. Semua parameter normal.Oil change, filter replace. All parameters normal.
!
14/4/2026 · Drift mulaiDrift begins
Pressure -100 psi dari baseline · severity MED · belum trigger alertPressure -100 psi from baseline · severity MED · alert didn't fire
!
18/4/2026 · Temp spikeTemp spike
Oil temperature 88°C (normal 68°C) · bearing sudah degrade signifikanOil temperature 88°C (normal 68°C) · bearing significantly degraded
20/4/2026 15:22 · Alert firedAlert fired
Pressure tembus 3.000 psi threshold · SMS ke Pak Dwi · tapi sudah terlambatPressure crossed 3,000 psi threshold · SMS to Mr. Dwi · but too late
22/4/2026 14:00 · BreakdownBreakdown
Pompa hidrolik total failure di tengah shift. Pak Sudarto trigger replan (Scene 9 Modul 1).Total hydraulic pump failure mid-shift. Mr. Sudarto triggered replan (Module 1 Scene 9).